oil soluble cycloalkyl imidazoline; Imidazoline Corrosive Inhibitor
UN3082 Class9 PGIII
17.1mts for 950kgs IBC
Availability: | |
---|---|
Specification
Item | Specification |
Appearance | Red-Brown liquid |
Density (25℃) , g/cm3 | 0.93-1.03 |
Solubleness | Evenly dissolve in methanol, ethanol, mixed benzener |
Effective content, % | ≥98 |
Application
1. Corrosion protection of crude oil and natural gas exploitation and gathering and transportation.
2. Anti-corrosion of atmospheric and vacuum pressure, catalytic cracking, hydrorefining, fractionating tower top in hydrocracking unit and condensing and cooling system.
3. Anti-corrosion of cooling water system operating under low and medium hardness, medium and high alkalinity and low concentration multiple.
4. Oil field sewage treatment and backwater injection system anti-corrosion.
5. Comprehensive water content, high CO2 gathering and transportation trunk lines and oil well corrosion prevention.
Packing and Storage
Packing: In 200kgs net plastic drum, or 1000kgs IBC drum
Storage: Keep tightly closed. Stored in cool and ventilated place. Do not approach open fire, acid, alkai and oxidant chemicals
Operational considerations
1. Operators should wear protective products such as latex gloves and protective glasses.
2. If the product touches the skin, it can be rinsed with plenty of water and then washed with soap;If the product is splashed into eyes, please wash it with water and seek advice immediately.
3. In case of fire, dry powder, foam, CO2 extinguisher and yellow sand extinguisher can be used.
Specification
Item | Specification |
Appearance | Red-Brown liquid |
Density (25℃) , g/cm3 | 0.93-1.03 |
Solubleness | Evenly dissolve in methanol, ethanol, mixed benzener |
Effective content, % | ≥98 |
Application
1. Corrosion protection of crude oil and natural gas exploitation and gathering and transportation.
2. Anti-corrosion of atmospheric and vacuum pressure, catalytic cracking, hydrorefining, fractionating tower top in hydrocracking unit and condensing and cooling system.
3. Anti-corrosion of cooling water system operating under low and medium hardness, medium and high alkalinity and low concentration multiple.
4. Oil field sewage treatment and backwater injection system anti-corrosion.
5. Comprehensive water content, high CO2 gathering and transportation trunk lines and oil well corrosion prevention.
Packing and Storage
Packing: In 200kgs net plastic drum, or 1000kgs IBC drum
Storage: Keep tightly closed. Stored in cool and ventilated place. Do not approach open fire, acid, alkai and oxidant chemicals
Operational considerations
1. Operators should wear protective products such as latex gloves and protective glasses.
2. If the product touches the skin, it can be rinsed with plenty of water and then washed with soap;If the product is splashed into eyes, please wash it with water and seek advice immediately.
3. In case of fire, dry powder, foam, CO2 extinguisher and yellow sand extinguisher can be used.
TEL: +86 21 33883180
E-MAIL: sales@sunwisechem.com
ADRESS: Room 10E, Building G, Westlink Center, No. 2337 Gudai Road, Minhang District, Shanghai, China PC: 201100
Copyright © 2021 Shanghai Sunwise Chemical Co., Ltd | Supported by leadong.com
备案号:沪ICP备07507527号-1
危化许可证编号:沪(闵)应急管危经许[2023]203636